Fisika & Matematika editorial
Open AccessOA2023
Broadband Quantum Enhancement of the LIGO Detectors with Frequency-Dependent Squeezing
Frequency-dependent squeezing was implemented in the LIGO Hanford and Livingston detectors, reducing both shot noise and quantum radiation pressure noise over a broad frequency range. This enhancement increased the detector range by 15โ18% and the astrophysical detection rate by up to 65%.
D. Ganapathy; W. Jia; M. Nakano; V. Xu; N. Aritomi; T. Cullen; N. Kijbunchoo; S. Dwyer; A. Mullavey; L. McCuller; R. Abbott; I. Abouelfettouh; R. Adhikari; A. Ananyeva; S. Appert; K. Arai; S. Aston; M. Ball; S. Ballmer; D. Barker; L. Barsotti; B. Berger; J. Betzwieser; D. Bhattacharjee; G. Billingsley; S. Biscans; N. Bode; E. Bonilla; V. Bossilkov; A. Branch; A. Brooks; D. Brown; J. Bryant; C. Cahillane; H. Cao; E. Capote; F. Clara; J. Collins; C. Compton; R. Cottingham; D. Coyne; R. Crouch; J. Csizmazia; L. Dartez; N. Demos; E. Dohmen; J. Driggers; A. Effler; A. Ejlli; T. Etzel; M. Evans; J. Feicht; R. Frey; W. Frischhertz; P. Fritschel; V. Frolov; P. Fulda; M. Fyffe; B. Gateley; J. Giaime; K. Giardina; J. Glanzer; E. Goetz; R. Goetz; A. Goodwin-Jones; S. Gras; C. Gray; D. Griffith; H. Grote; T. Guidry; E. Hall; J. Hanks; J. Hanson; M. Heintze; A. Helmling-Cornell; N. Holland; D. Hoyland; H.-Y. Huang; Y. Inoue; A. James; A. Jennings; S. Karat; S. Karki; M. Kasprzack; K. Kawabe; P. King; J. Kissel; K. Komori; A. Kontos; R. Kumar; K. Kuns; M. Landry; B. Lantz; M. Laxen; K. Lee; M. Lesovsky; F. Llamas; M. Lormand; H. Loughlin; R. Macas; M. MacInnis; C. Makarem; B. Mannix; G. Mansell; R. Martin; K. Mason; F. Matichard; N. Mavalvala; N. Maxwell; G. McCarrol; R. McCarthy; D. Mcclelland; S. McCormick; T. McRae; F. Mera; E. Merilh; F. Meylahn; R. Mittleman; D. Moraru; G. Moreno; T. Nelson; A. Neunzert; J. Notte; J. Oberling; T. O'Hanlon; C. Osthelder; D. Ottaway; H. Overmier; W. Parker; A. Pele; H. Pham; M. Pirello; V. Quetschke; K. Ramirez; J. Reyes; J. Richardson; M. Robinson; J. Rollins; C. Romel; J. Romie; M. Ross; K. Ryan; T. Sadecki; A. Sanchez; E. Sanchez; L. Sanchez; R. Savage; D. Schaetzl; M. Schiworski; R. Schnabel; R. Schofield; E. Schwartz; D. Sellers; T. Shaffer; R. W. Short; D. Sigg; B. Slagmolen; C. Soike; S. Soni; V. Srivastava; L. Sun; D. Tanner; M. Thomas; P. Thomas; K. Thorne; C. Torrie; G. Traylor; A. Ubhi; G. Vajente; J. Vanosky; A. Vecchio; P. Veitch; A. Vibhute; E. V. von Reis; J. Warner; B. Weaver; R. Weiss; C. Whittle; B. Willke; C. Wipf; H. Yamamoto; L. Zhang; M. Zuckerยท Physical Review Xยท 2023ยท DOI 10.1103/physrevx.13.041021
The core problem
Quantum noise fundamentally limits the sensitivity of interferometric gravitational-wave detectors such as LIGO. It arises from two coupled effects: shot noise, which dominates at high frequencies due to photon counting statistics, and quantum radiation pressure noise, which dominates at low frequencies due to momentum transfer from fluctuating photon number. The uncertainty principle relates these noises: reducing one typically increases the other. Frequency-dependent squeezing (FDS) offers a way to redistribute quantum uncertainty optimally across the detection band, but until now it had not been realized in full-scale gravitational-wave detectors. This work reports the first implementation of FDS in the LIGO Hanford and Livingston detectors, enabled by the addition of 300-meter-long filter cavities as part of the LIGO A+ upgrade.
Innovation
The FDS system uses a squeezed light source and a filter cavity to produce a frequency-dependent squeezing angle. The filter cavity, 300 m long, rotates the squeezing ellipse as a function of frequency: at low frequencies, the squeezing is oriented to reduce radiation pressure noise, while at high frequencies it reduces shot noise. The squeezed light is injected into the interferometer's dark port. The experiment was conducted during the LIGO A+ upgrade, with the system installed in both the Hanford and Livingston detectors. The performance was characterized by measuring the detector noise power spectral density with and without squeezing, and by evaluating the impact on detector range and astrophysical detection rate.
Introduction
Quantum noise fundamentally limits the sensitivity of interferometric gravitational-wave detectors such as LIGO. It arises from two coupled effects: shot noise, which dominates at high frequencies due to photon counting statistics, and quantum radiation pressure noise, which dominates at low frequencies due to momentum transfer from fluctuating photon number. The uncertainty principle relates these noises: reducing one typically increases the other. Frequency-dependent squeezing (FDS) offers a way to redistribute quantum uncertainty optimally across the detection band, but until now it had not been realized in full-scale gravitational-wave detectors. This work reports the first implementation of FDS in the LIGO Hanford and Livingston detectors, enabled by the addition of 300-meter-long filter cavities as part of the LIGO A+ upgrade.
Why it matters
The results demonstrate that frequency-dependent squeezing can be successfully implemented in full-scale gravitational-wave detectors, simultaneously reducing shot noise and quantum radiation pressure noise. This represents a significant step beyond frequency-independent squeezing, which only reduces shot noise and can increase radiation pressure noise at low frequencies. The broadband enhancement improves both the high-frequency sensitivity for postmerger signals and the low-frequency sensitivity for longer-duration inspirals, thereby increasing the volume of the observable universe and the detection rate. The success of FDS in LIGO A+ validates the filter cavity technology and paves the way for further quantum noise reduction in future upgrades such as LIGO Voyager and Cosmic Explorer. The 300-meter filter cavities are a key enabling technology for these next-generation detectors.